Error code 1
Fan speed x fallen short of
Warning at Drill and Maestro.Drill (1-1)
since version 9.65
Maestro (1-2)
since version 9.65
When does the warning occur?
Fan speed too low.
Limiting values for fan speed, which leads to an error message, can be configured.
Compliance with the set values is not possible.
Limiting values for fan speed, which leads to an error message, can be configured.
Compliance with the set values is not possible.
Does a Drilling error (drilling drop-out) occur?
Yes!
What to do?
- Increase the fan speed.
- Check sensor function, pulse counting in the diagnostics.
- Sensor position too close, to far away, check.
- Check the limiting values in the machine configuration.
- Check the adjusted pulses.
Is there an audible indication?
single audible signal
How is the warning confirmed?
not possible, until error has been rectified